WHEELCHAIR CPAP HOSPITAL BEDS PORTABLE OXYGEN CONCENTRATOR SCOOTER RENTAL PRIDE MOBILITY MEDICAL RECLINER TRANSFORMER ATTO DRIVE NITRO RAZ SHOWER
The mattress utilizes 18 independent 9″ deep air cells to provide proper pressure redistribution for the prevention and treatment of Stages I-IV pressure ulcers. The new Power-Pro™ VW Elite bariatric model combines variable width convenience with durability and wound prevention features. Available in three models to fit the most popular bariatric bed frames.The Power-Pro VW Elite fits 35”, 39”, 42”, 48” and 54” bed frames. The Power-Pro™ Elite Alternating Pressure Air Mattress System with Gentle Low Air Loss supports patients weighing up to 1000 pounds. Audible alarm system alerts caregiver of power outages.
Bladders:Ventilated low air loss cells have air holes throughout the mattress to helpminimize skin maceration by reducing excess moisture under patient. The ventilated air cells assist in the treatment and prevention of pressure ulcers. Air cells are constructed of TPU thermal polyurethane material. Dual bladder design prevents patients from bottoming out, while sitting up and will maintain air during power outages.
Optional Expandable Mattress:Power Pro™ VW is an expandable air mattress system that allows for variable mattress widths. Three models 35″, 39″, 42″ supporting 800 lbs, 35″, 42″, 48″ supporting 1000 lbs and 39″, 48″, 54″ bariatric mattress supports 1000 lbs.
Cover:Vyvex – III™ - Urethane coated, multi-stretch, moisture resistant / vapor permeable, low shear, quilted cover, transfers moisture away from the patient’s skin. The cover is washable, anti-microbial, fluid-resistant and fire-retardant.
Hose connectionsHose connections feature a transport locking device that ensures the mattress remains inflated for patient transport.CPR ValveCPR Valve quickly deflates mattress system for medical emergencies. A simple twist releases air immediately.
Blower PumpThe blower pump is controlled by a micro-processor which allows the caregiver total control of comfort and chosen therapy. Cycle time ranges from 5 to 95 minutes. The blower pump inflates the mattress within minutes, reducing the waiting time for therapeutic treatment to begin. Optional pulsating low air loss pump Model 9511-PS allows caregivers to provide pulsating low air loss therapy.
MODEL 9500
Power-Pro Elite ™Alternating Pressure Air Mattress – Mattress and Pump
Dimensions:
36″ x 80″ x 9″
Weight:
23 lbs.
Air Cells:
18 – 9 ” deep cellsVentilated bladders with air holes throughout mattress
Mattress Cover:
Vyvex-III™ - Urethane coated, multi-stretch, low shear, moisture resistant / vapor permeable quilted cover. Removable, zippered cover, is anti-microbial and meets California Technical Bulletin #117 for fire-retardancy.
MODEL 9501
Power-Pro Elite ™ - Pump only
17″L x 7″W x 10.5″H
12 lbs.
Electrical:
120V 60 hz
Listings:
UL® 544 Medical Equipment
Cycle Time:
5 – 95 Minutes
Air Flow:
1800 Liters per minute
Current:
5A
Ground Resistance:
0.1 ohms maximum
Power Cord:
12 ft. cord with hospital grade plug
WARRANTY
Pumps:
1 Year limited
Mattress:
1 year limited
Cover:
6 months limited
ORDERING INFORMATION
Model 9500
Power Pro™ Elite 650 lbs. capacity 36″ x 80″ x 9″
Model 9542BAR
Power Pro™ Elite 750 lbs. capacity 42″ x 80″ x 9″
Model 9548BAR
Power Pro™ Elite 1000 lbs. capacity 48″ x 80″ x 9″
Model 9511
Power Pro™ Elite Blower pump only
Model 9511-PS
Power Pro™ Elite Blower pump with pulsating low air loss
Model 9502
Power Pro™ Mattress only with Zippered Quilted Cover 36″
Model 9502-42
Power Pro™ Mattress only with Zippered Quilted Cover 42″
Model 9502-48
Power Pro™ Mattress only with Zippered Quilted Cover 48″
Model 9500-EXP-1
Power Pro™ Mattress Variable Width 35″ – 39″ – 42″, 800 lbs
Power Pro™ Mattress Variable Width 35″ – 42″ – 48″, 1000 lbs
Power Pro™ Mattress Variable Width 39″ – 48″ – 54 “, 1000 lbs
PDAC APPROVED
Medicare Code EO277
Power Pro™ Elite meets Group 2 Support Surface requirements for Medicare EO277. Patient must meet all medical criteria to qualify for reimbursement.